Discovery HR-1 hybrid rheometerTA Instruments
HR-1
Discovery HR-1 hybrid rheometer
TA Instruments
HR-1
Precio fijo IVA no incluído
EUR 19.000
Estado
Usado
Ubicación
Żychlin 

Datos básicos
- Descripción de la máquina:
- Discovery HR-1 hybrid rheometer
- Fabricante:
- TA Instruments
- Modelo:
- HR-1
- Estado:
- como nuevo (usado)
Precio y ubicación
Precio fijo IVA no incluído
EUR 19.000
- Ubicación:
- ul Narutowicza 44-10, 99-320 Żychlin, Polska

Llamar
Detalles de la oferta
- ID del anuncio:
- A20739417
- Actualización:
- última actualización el 12.10.2026
Descripción
TA Instruments Discovery HR-1 – Hybrid Rheometer with Temperature Chamber
Technical description of the device
Manufacturer: TA Instruments, USA
Model: Discovery HR-1
Series: Discovery Hybrid Rheometer
Device type: Rotational-oscillatory rheometer
Temperature system: Two-wing heating chamber, possibly an ETC (Environmental Test Chamber)
Technical characteristics
The TA Instruments Discovery HR-1 is an advanced hybrid rheometer designed for the precise investigation of the rheological properties of liquids, semi-finished products, polymers, pastes, gels, and viscoelastic materials.
The device enables measurements in controlled stress mode, controlled shear rate mode, and oscillatory testing.
The rheometer's design utilizes a precise drive system, a torque measurement system, and a gap control system.
Technical parameters – Discovery HR-1
The following values are approximate catalog parameters for the HR-1 model and require confirmation for a specific device version.
Parameter | Value
----- | -----
Type of measurement | Rotational and oscillatory
Minimum oscillatory torque | approx. 0.5 nNm
Minimum rotational torque | approx. 10 nNm
Maximum torque | 150 mNm
Angular speed range | up to 300 rad/s
Oscillatory frequency range | up to 100 Hz
Angular displacement resolution | approx. 10 nrad
Gap control | Automatic
Control modes | Stress, shear rate, oscillation
Computer control | TA Instruments TRIOS software
Temperature control system
The device shown in the pictures is equipped with a two-part heating system that opens to the sides.
The chamber enables rheological measurements to be carried out under controlled temperature conditions.
System characteristics:
* Two-wing design of the heating chamber.
* Electric heating system.
* Temperature control of the sample.
* Possibility of conducting temperature studies.
* Thermally insulated chamber elements.
* Connections for the temperature control system.
If the use of an ETC chamber is confirmed, the typical temperature range may be approximately -160°C to +600°C, depending on the configuration, cooling system, and accessories used. This range is not confirmed for the offered unit.
Available research methods
Rotational studies:
* Viscosity measurement as a function of shear rate.
* Determination of flow curves.
* Study of the yield point.
* Analysis of the behavior of non-Newtonian materials.
Oscillatory studies:
* Measurement of the storage modulus G'.
* Measurement of the loss modulus G''.
* Analysis of the loss tangent tan δ.
* Frequency tests.
* Amplitude tests.
* Analysis of structural transitions of materials.
Time and temperature studies:
* Creep and recovery tests.
* Stress relaxation.
* Thermal stability studies.
* Analysis of changes in rheological properties as a function of temperature and time.
Configuration of the offered device
Based on the photographic documentation, the set includes:
Credpjx E Sm Hefx Ap Aji
1. TA Instruments Discovery HR1 rheometer
2. Two-wing temperature chamber.
3. Accessories visible in the pictures
4. PC and software
The device is a professional measurement platform designed for advanced rheological analyses in industrial and scientific laboratories.
El anuncio se tradujo automáticamente y se pueden haber producido errores de traducción.
Technical description of the device
Manufacturer: TA Instruments, USA
Model: Discovery HR-1
Series: Discovery Hybrid Rheometer
Device type: Rotational-oscillatory rheometer
Temperature system: Two-wing heating chamber, possibly an ETC (Environmental Test Chamber)
Technical characteristics
The TA Instruments Discovery HR-1 is an advanced hybrid rheometer designed for the precise investigation of the rheological properties of liquids, semi-finished products, polymers, pastes, gels, and viscoelastic materials.
The device enables measurements in controlled stress mode, controlled shear rate mode, and oscillatory testing.
The rheometer's design utilizes a precise drive system, a torque measurement system, and a gap control system.
Technical parameters – Discovery HR-1
The following values are approximate catalog parameters for the HR-1 model and require confirmation for a specific device version.
Parameter | Value
----- | -----
Type of measurement | Rotational and oscillatory
Minimum oscillatory torque | approx. 0.5 nNm
Minimum rotational torque | approx. 10 nNm
Maximum torque | 150 mNm
Angular speed range | up to 300 rad/s
Oscillatory frequency range | up to 100 Hz
Angular displacement resolution | approx. 10 nrad
Gap control | Automatic
Control modes | Stress, shear rate, oscillation
Computer control | TA Instruments TRIOS software
Temperature control system
The device shown in the pictures is equipped with a two-part heating system that opens to the sides.
The chamber enables rheological measurements to be carried out under controlled temperature conditions.
System characteristics:
* Two-wing design of the heating chamber.
* Electric heating system.
* Temperature control of the sample.
* Possibility of conducting temperature studies.
* Thermally insulated chamber elements.
* Connections for the temperature control system.
If the use of an ETC chamber is confirmed, the typical temperature range may be approximately -160°C to +600°C, depending on the configuration, cooling system, and accessories used. This range is not confirmed for the offered unit.
Available research methods
Rotational studies:
* Viscosity measurement as a function of shear rate.
* Determination of flow curves.
* Study of the yield point.
* Analysis of the behavior of non-Newtonian materials.
Oscillatory studies:
* Measurement of the storage modulus G'.
* Measurement of the loss modulus G''.
* Analysis of the loss tangent tan δ.
* Frequency tests.
* Amplitude tests.
* Analysis of structural transitions of materials.
Time and temperature studies:
* Creep and recovery tests.
* Stress relaxation.
* Thermal stability studies.
* Analysis of changes in rheological properties as a function of temperature and time.
Configuration of the offered device
Based on the photographic documentation, the set includes:
Credpjx E Sm Hefx Ap Aji
1. TA Instruments Discovery HR1 rheometer
2. Two-wing temperature chamber.
3. Accessories visible in the pictures
4. PC and software
The device is a professional measurement platform designed for advanced rheological analyses in industrial and scientific laboratories.
El anuncio se tradujo automáticamente y se pueden haber producido errores de traducción.
Proveedor
Nota: Regístrese gratis o inicie sesión, para ver toda la información.
La última vez en línea: La semana pasada
Registrado desde: 2019
42 anuncios online
Enviar solicitud
Teléfono & Fax
+48 793 1... mostrar
También puede estar interesado en estos anuncios.
Con éxito:
Su mensaje ha sido enviado.
Clasificado
Ybbs an der Donau
12.372 km
Espectrómetro FTIR - NICOLET IS20
ThermoFisher ScientificNICOLET IS20
ThermoFisher ScientificNICOLET IS20
Con éxito:
Su mensaje ha sido enviado.
Clasificado
Alfdorf
12.097 km
Plataforma industrial Carro de transporte
Stapler Center Fritz GmbHTPW 10 AL - AS
Stapler Center Fritz GmbHTPW 10 AL - AS
Con éxito:
Su mensaje ha sido enviado.
Clasificado
Contamine-sur-Arve
11.708 km
Lapeadora
PEMAMOMVR 060 EH
PEMAMOMVR 060 EH
Con éxito:
Su mensaje ha sido enviado.
Clasificado
Budapest
12.577 km
Rotavapor
BüchiR-200
BüchiR-200
Con éxito:
Su mensaje ha sido enviado.
Clasificado
Borken
12.144 km
Reómetro rotacional HAAKE RheoStress 6000 – Thermo Scientific Tipo: 006-1512
Thermo Fisher ScientificThermo Haake 006-1512
Thermo Fisher ScientificThermo Haake 006-1512
Su anuncio ha sido borrado con éxito
Se produjo un error